Separating the Media

Procedure
  1. Close the front cover.
  2. Check that [SETUP] is lit.
  3. Press [FUNCTION].
  4. Press [▼] several times to display the screen shown below.


  5. Press [ENTER].
    From its position on the blade protection line prior to [ENTER] being pressed (), the media moves to a position on the separating line () and is separated.

    If is obscured by the media clamp, use the two lines () on the media clamp as a guide.



    MEMO:

    You can configure settings in the software RIP for automatic media separation after output has finished. For information on how to configure the settings, refer to the documentation for the software RIP you are using.

    IMPORTANT:

    Separation Operations

    • When performing separation, do not use [▲] to pull the media back. If the distance from the end of the media to the separation location is short, separation may not be performed smoothly.
    Give Attention to the Media Composition
    • For some types of media, separation is not possible.
    • Some types of media may remain on the platen after separation. If the media remains on the platen, remove it by hand.